Here\’s what I did using the NI-DAQmx simulation mode:

– create two tasks
Analog Output – 4 channels, 1k output rate, 100 samples to write, Continuous
Analog Input – 4 channels, 1k input rate, 100 samples to read, Continuous

Save them. Start up or synchronize DASYLab (Under Measurement Boards Settings – NI-DAQmx – Synchronize with… in earlier versions, it\’s under Hardware Setup)

– Create Slider. Open Slider properties, click on Options, Synchronize to the AO task that you created. This step is really important – it ensures that the data rate matches what NI-DAQmx is expecting.

– Connect Slider to NI-DAQmx AO module, configured for 4 channels.

– Create AI module. Connect to the AI task that you created.

Press Start. It should run. I can\’t verify absolute accuracy in simulation mode, but, I received no errors.

Your first error is probably the result of the timing being wrong – the Slider defaults to the \”Driver\” timebase. The rest of the errors seem to be a cascade off the first.

Note – my simulation did not work without the Analog Input. It generated no data. That may be an artifact of the simulator, but, once I put an Analog Input on the worksheet, it ran okay.